=== Digital outputs === [[File:Output-Lamp.svg|left]] The digital outputs are designed to drive lower power devices than the motor outputs, any one load should not exceed 400mA. The total maximum load for all the digital outputs is 600mA. Again for most small devices this is more than adequate. A typical buzzer would take 25mA and a bulb between 40 and 60mA. The total safe maximum load for all outputs, i.e. digital outputs and motor outputs together in any combination, is 1.5A. {{Template:Clear}}